一氧化碳分析儀CO-180英文說明書
點擊次數(shù):2156 更新時間:2015-10-19

一氧化碳分析儀CO-180英文說明書

Carbon Monoxide Meter

Instruction Sheet


Introduction

The Carbon Monoxide Meter detects the presence of carbon monoxide

(CO) and measures concentrations between 1-1000 parts per million (PPM).

The Meter indicates the presence of carbon monoxide in two ways:

·By a reading on the LCD in PPM.

·By a beeper tone.


Safety Information-Read First

·Do not use the Meter as a personal safety monitor.

·Learn and recognize the effects of CO poisoning.

0-1PPM

Normal background levels.

9 PPM

ASHRAE Standard 62-1989 for living areas.

50 PPM

OSHA enclosed space 8-hour average level.*

100 PPM

OSHA exposure limit.*

200 PPM

Mild headache, fatigue, nausea and dizziness.

800 PPM

Dizziness, nausea and convulsions.

Death within 2 to 3 hours.

*U.S. Department of Labor, Occupational Safety & Health Administration (OSHA) Regulation 1917.24: The CO content in any enclosed space shall be maintained at not more than 50 PPM (0.005%). Remove employees from enclosed space if the CO concentration exceeds 100 PPM(0.01%).


What the Meter Does

The Meter indicates the presence of CO by a reading on the LCD and a beeper tone.

The beeper functions much like clicking of a Geiger counter:

·Above 200 PPM, the beeper sounds continuously with the concentration of CO.

·From 35 PPM to 200 PPM, the beeper sounds discontinuously with the

concentration of CO.


Specifications

Temperature

Operating:

Storage:


0 to + 50

-30 to + 60

Operating humidity

0-99% Relative humidity (non-condensing)

Measurement range

0 to 1000PPM

Measurement Resolution

1PPM

Accuracy

±5% or ± 10 PPM

Warm up period

<2 seconds

Battery

9V, NEDA 1604A or IEC 6LR61, or equivalent.

Auto power off

Meter automatically shuts down after 15 minutes of inactivity

Sensor type

Stabilized electrochemical Gas-specific (CO)

Typical sensor life

3 years


Instrument Familiarization:


 


  1. CO sensor
  2. LCD Display
  3. MAX Hold button
  4. Data Hold button
  5. Back-light button
  6. Power button
  7. Battery door


DATA HOLD

The Data Hold function allows the meter to “freeze" a measurement for later reference.

  1. Press the DATA HOLD button to “freeze" the reading on the indicator.

The indicator “HOLD" will be appear in the display.

  1. Press the DATA HOLD button to return to normal operation.


MAX Hold

To hold the highest reading on the LCD, press the MAX hold button. The MAX hold button is located on the left side of the meter (bottom button). The meter reading will not change as readings change, rather it will only display the highest reading encountered since the MAX hold button was pressed. Press the MAX hold button again to return to normal operation.


BACKLIGHT BUTTON

  1. Press the “BACKLIGHT" key, the “l(fā)ight" will be appear in the display.
  2. Press it again, the “l(fā)ight" close.


POWER BUTTON

  1. Press the power button, power is on and the meter can measure.
  2. Pull it again, Power is off.


BATTERY REPLACEME

  1. As battery power is not sufficient, LCD will display “     " replacement with one battery type 9V is required.
  2. Open battery cover, then take out the battery from instrument and replace with a new 9-Volt battery and place the battery cover back.


Common Sources of CO

Common sources of potentially dangerous levels of CO are:

· Poorly maintained furnaces, gas heaters, or fireplaces.

· Dirty or plugged chimneys, or flue exhausts.

· Poorly maintained gas, oil, or kerosene appliances.

· Internal combustion engines (e.g., autos, lawnmowers, blowers).


CO and Appliance Malfunctions

The following table identifies typical problems that can produce high levels of CO.

Appliance

Fuel

Typical Problems

Gas furnaces

Room heaters

Oil, natural gas, or LPG

(liquefied petroleum gas)

1. Cracked heat exchanger.

2. Not enough air to burn fuel properly.

3. Defective/blocked flue.

4. Maladjusted burner.

5. Building not properly pressurized.

Central heating

furnaces

Coal or kerosene

1. Cracked heat exchanger.

2. Not enough air to burn fuel properly.

3. Defective grate.

Room heaters

Central heaters

Kerosene

1. Improper adjustment.

2. Wrong fuel (not K-1).

3. Wrong wick or wick height.

4. Not enough air to burn fuel.

5. System not properly vented.

Water heaters

Natural gas or LPG

1. Not enough air to burn fuel properly.

2. Defective/blocked flue.

3. Maladjusted burner.

4. Building not properly pressurized.

Ranges Ovens

Natural gas or LPG

1. Not enough air to burn fuel.

2. Maladjusted burner.

3. Misuse as a room heater.

4. System not properly vented.

Stoves Fireplaces

Gas, wood, coal

1. Not enough air to burn fuel properly.

2. Defective/blocked flue.

3. Green or treated wood.

4. Cracked heat exchanger.

5. Cracked firebox.


CO-180一氧化碳檢測儀可探測一氧化碳的存在和檢測百萬分之1-1000(PPM)之間的一氧化碳濃度。
此表通過兩種途徑表明一氧化碳的存在:
·通過液晶顯示屏上顯示PPM讀數(shù)
·通過蜂鳴提示

特征

1.取樣速度快
2.zui大值保持
3.數(shù)據(jù)保持功能
4.自動關機功能
5.一氧化碳濃度在200 PPM以上時,蜂鳴聲連續(xù)響
此檢測儀通過LCD上顯示讀數(shù)和蜂鳴聲來提示CO的存在。蜂鳴聲:
·一氧化碳濃度在200 PPM以上時,蜂鳴聲連續(xù)響。
·一氧化碳濃度在35 PPM 200 PPM之間時,蜂鳴聲間續(xù)響

技術參數(shù):

操作溫度

0oC ~ 50oC

貯藏溫度

-30oC ~ 60oC

操作濕度

相對濕度0-99% (不冷凝)

量程

0 ~ 1000PPM

分辨率

1PPM

±5% ± 10 PPM

反映時間

<2

電池

9V, NEDA 1604A IEC 6LR61,或相同規(guī)格其他電池

自動關機

靜置15分鐘后儀表自動關機

傳感器類型

Stabilized electrochemical Gas-specific (CO)

尺寸(HxD)

160x56x40mm

重量

180g


標準配置:9V電池,護套,彩盒,帆布袋